[35] | SiPM based preclinical PET/MR insert for a human 3T MR: first imaging experiments (Schulz V., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[34] | Strategy for calibrating the non-linear gain of the DSSC detector for the European XFEL (Andritschke G. Wand R., et al.), In 2011 IEEE Nuclear Science Symposium Conference Record, 2011. |
[33] | The DAQ readout chain of the DSSC detector at the European XFEL (Gerlach T., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[32] | An FPGA-based readout module for the DAQ subsystem of the DSSC detector at the European XFEL (Gerlach T, et al.), In 2012 18th IEEE-NPSS Real Time Conference, 2012. |
[31] | Multi-channel charge pulse amplification, digitization and processing ASIC for detector applications (Armbruster T., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE, 2012. |
[30] | The APA pixel readout ASIC for an APD based fast 2D X-ray hybrid pixel detector (Thil C., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE, 2012. |
[29] | The DSSC pixel readout ASIC with amplitude digitization and local storage for DEPFET sensor matrices at the European XFEL (Erdinger F, et al.), In , 2012. |
[28] | STiC2 - characterization results of a SiPM readout ASIC for time-of-flight applications (Shen W, et al.), In 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), volume , 2013. |
[27] | Strip Technology and HVMAPS (Peric I, et al.), In Proceedings of The 21st International Workshop on Vertex Detectors PoS(Vertex 2012), Sissa Medialab, 2013. |
[26] | The PPT-module: High-performance readout for the DSSC detector at XFEL (Kugel A., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE, 2013. |
[25] | A new position-sensitive silicon photomultiplier with submillimeter spatial resolution for photon-cluster identification (Sacco I, et al.), In , 2013. |
[24] | A dedicated readout ASIC for Time-of-Flight Positron Emission Tomography using Silicon Photomultiplier (SiPM) (Briggl H. Cand K., et al.), In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2014. |
[23] | A compact, water-cooled, 144-channel photo sensor module for γ detection in PET (Dohle I. Sand R., et al.), In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2014. |
[22] | Very compact, water-cooled SiPM module for PET/MRT applications (Rittweg R. Dand T., et al.), In 2015 European Microelectronics Packaging Conference (EMPC), 2015. |
[21] | Calibration of the non-linear system characteristic of the DSSC detector for the European XFEL (Weidenspointner G., et al.), In 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), IEEE, 2015. |
[20] | Calibration of the non-linear system characteristic of the DSSC detector for the European XFEL (Moch G. Wand D., et al.), In 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2015. |
[19] | Status of the EPICS-Based Control and Interlock System of the Belle II PXD (Ritzert M.), In Proc. of International Conference on Accelerator and Large Experimental Physics Control Systems (ICALEPCS'15), Melbourne, Australia, 17-23 October 2015, JACoW, 2015. |
[18] | Interfacing EPICS to the Widespread Platform Management Interface IPMI (Ritzert M.), In Proc. of International Conference on Accelerator and Large Experimental Physics Control Systems (ICALEPCS'15), Melbourne, Australia, 17-23 October 2015, JACoW, 2015. |
[17] | First operation of a DSSC hybrid 2D soft X-ray imager with 4.5 MHz frame rate (Comotti J. Sand D., et al.), In 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), volume , 2016. |
[16] | Study of PMOS front-end solution with signal compression for XFEL MiniSDD X-ray detectors (Grande A, et al.), In , 2016. |