[56] | Front-end electronics for DEPFET pixel detectors at SuperBelle (BELLE II) (Krüger H), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 617, 2010. |
[55] | Large monolithic particle pixel-detector in high-voltage CMOS technology (Perić I., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 624, 2010. |
[54] | Hybrid pixel detector based on capacitive chip to chip signal-transmission (Perić I., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 617, 2010. |
[53] | Expected performance of the DEPFET sensor with signal compression: A large format X-ray imager with mega-frame readout capability for the European XFEL (Porro M., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 624, 2010. |
[52] | The DEPFET active pixel sensor for vertexing at ILC and Super KEKB (Rummel S, et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 623, 2010. |
[51] | DCD - The Multi-Channel Current-Mode ADC Chip for the Readout of DEPFET Pixel Detectors (Perić I., et al.), In Nuclear Science, IEEE Transactions on, volume 57, 2010. |
[50] | SPADIC: A self-triggered pulse amplification and digitization ASIC (Armbruster T., et al.), In Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE, 2010. |
[49] | A 5MHz low-noise 130nm CMOS analog front-end electronics for the readout of non-linear DEPFET sensor with signal compression for the European XFEL (Vita G. D, et al.), In Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE, 2010. |
[48] | Compact digital memory blocks for the DSSC pixel readout ASIC (Erdinger F., et al.), In Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE, 2010. |
[47] | Pixel readout ASIC with per pixel digitization and digital storage for the DSSC detector at XFEL (Fischer P., et al.), In Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE, 2010. |
[46] | Particle pixel detectors in high-voltage CMOS technology-New achievements (Perić I., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 650, 2011. |
[45] | The first beam test of a monolithic particle pixel detector in high-voltage CMOS technology (Perić I., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 628, 2011. |
[44] | Particle pixel detectors in high-voltage CMOS technology - New achievements (Perić I., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 650, 2011. |
[43] | Pixel readout ASIC for an APD based 2D X-ray hybrid pixel detector with sub-nanosecond resolution (Thil C., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 628, 2011. |
[42] | Characterization of the Flip Capacitor Filter for the XFEL-DSSC Project (Facchinetti S., et al.), In Nuclear Science, IEEE Transactions on, volume 58, 2011. |
[41] | Fast, low-noise, low-power electronics for the analog readout of non-linear DEPFET pixels (Facchinetti S., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[40] | Floodmap measurement of a pixellated gamma scintillation detector module using fully integrated readout (Mlotok V., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[39] | DCDB and SWITCHERB, the readout ASICS for Belle II DEPFET pixel detector (Perić I., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[38] | SiPM based preclinical PET/MR insert for a human 3T MR: first imaging experiments (Schulz V., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[37] | Strategy for calibrating the non-linear gain of the DSSC detector for the European XFEL (Andritschke G. Wand R., et al.), In 2011 IEEE Nuclear Science Symposium Conference Record, 2011. |