[25] | Clear-performance of linear DEPFET devices (Sandow C., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 568, 2006. |
[24] | Study of noise and spectroscopic performance of DEPMOSFET matrix prototypes for XEUS (Treis J., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 568, 2006. |
[23] | Performance of a DEPFET pixel system for particle detection (Trimpl M., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 568, 2006. |
[22] | A DEPFET pixel matrix system for the ILC vertex detector (Trimpl M., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 560, 2006. |
[21] | Performance of a DEPFET prototype module for the ILC vertex detector (Reuen L., et al.), In Nuclear Science, IEEE Transactions on, volume 53, 2006. |
[20] | Progress towards a large area, thin DEPFET detector module (Fischer P., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 582, 2007. |
[19] | A DEPFET Based Beam Telescope With Submicron Precision Capability (Velthuis J. J., et al.), In Nuclear Science, IEEE Transactions on, volume 55, 2008. |
[18] | Front-end electronics for DEPFET pixel detectors at SuperBelle (BELLE II) (Krüger H), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 617, 2010. |
[17] | Expected performance of the DEPFET sensor with signal compression: A large format X-ray imager with mega-frame readout capability for the European XFEL (Porro M., et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 624, 2010. |
[16] | The DEPFET active pixel sensor for vertexing at ILC and Super KEKB (Rummel S, et al.), In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, volume 623, 2010. |
[15] | DCD - The Multi-Channel Current-Mode ADC Chip for the Readout of DEPFET Pixel Detectors (Perić I., et al.), In Nuclear Science, IEEE Transactions on, volume 57, 2010. |
[14] | A 5MHz low-noise 130nm CMOS analog front-end electronics for the readout of non-linear DEPFET sensor with signal compression for the European XFEL (Vita G. D, et al.), In Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE, 2010. |
[13] | Compact digital memory blocks for the DSSC pixel readout ASIC (Erdinger F., et al.), In Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE, 2010. |
[12] | Pixel readout ASIC with per pixel digitization and digital storage for the DSSC detector at XFEL (Fischer P., et al.), In Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE, 2010. |
[11] | Characterization of the Flip Capacitor Filter for the XFEL-DSSC Project (Facchinetti S., et al.), In Nuclear Science, IEEE Transactions on, volume 58, 2011. |
[10] | Fast, low-noise, low-power electronics for the analog readout of non-linear DEPFET pixels (Facchinetti S., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[9] | DCDB and SWITCHERB, the readout ASICS for Belle II DEPFET pixel detector (Perić I., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[8] | The DAQ readout chain of the DSSC detector at the European XFEL (Gerlach T., et al.), In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE, 2011. |
[7] | DEPFET Active Pixel Detectors for a Future Linear $ e^+e^- $ Collider (Alonso O., et al.), In Nuclear Science, IEEE Transactions on, volume 60, 2013. |
[6] | Pixel-Level Charge and Current Injection Circuit for High Accuracy Calibration of the DSSC Chip at the European XFEL (Comotti M. Mand D., et al.), In IEEE Transactions on Nuclear Science, volume 60, 2013. |